1、 The fragrant feet are not neat

                                                  01. Check whether the space between the toe board and the nozzle is too large?

                                                  02. Check whether the bamboo stick is against the cutting board without leaving a 1 mm distance?

                                                  03. Check whether the cutting board is not tightened, whether the cutting board is neat and parallel, and whether the bamboo stick is within the scope of the cutting board?

                                                  04. Look at the speed of the governor of the main engine. If it is too fast, adjust it slowly; if it is too slow, adjust it quickly.

                                                  05. The fragrant feet are longer than the budget. Adjust the pressure sensor at the back to the left a little, and adjust it to the right if it is shorter than the budget.


                                                  2、 Nozzle clogging

                                                  01. If the perfume emitted from the nozzle is not full, flat or torn, it means that the nozzle is blocked by impurities.

                                                  02. In the process of Buddhist incense injection, the nozzle is blocked if the card and powder are excluded.

                                                  03. The surface of the spray incense body is incomplete and cracked, indicating that there are impurities blocking the nozzle.

                                                  04. There is a small section of the spray nozzle without powder, which indicates that the nozzle is blocked by impurities.

                                                  05. Nozzle clogging treatment: twist out the nozzle with a wrench, remove the powder and impurities in the nozzle, and then tighten it.




                                                  Comparison of nozzle, catheter and bamboo stick

                                                  injector

                                                  catheter

                                                  Using bamboo sticks

                                                  2.5mm

                                                  One point six

                                                  1.0mm-1.2mm

                                                  3.0mm

                                                  One point nine

                                                  1.3mm

                                                  3.5mm

                                                  Two

                                                  3.1-1.4mm

                                                  4.0mm

                                                  Two point two

                                                  1.4-1.6mm

                                                  4.5mm

                                                  Two point four

                                                  1.6mm

                                                  5.0mm

                                                  Two point six

                                                  1.6-1.8mm

                                                  5.5mm

                                                  Two point eight

                                                  1.8mm

                                                  6.0mm

                                                  Two point eight

                                                  1.8mm